Agilent OpenLab CDS
.dx data / AcqData, .pmx processing methods, AgilentOpenLab providers; not MassHunter.
How Quanto reads Agilent OpenLab CDS sample data (.dx / AcqData layout) and imports OpenLab processing methods (.pmx). OpenLab is not MassHunter and not classic ChemStation — use the OpenLab add-ins below. For MassHunter .D + MSTree2.bin, see MassHunter. For ChemStation data.ms / qdb.mth, see ChemStation / MSD.
Raw data
| Item | Notes |
|---|---|
| Sample / result data | .dx (OpenLab result / AcqData layout) |
| How you add it | Batch → Add samples — OpenLab data is loaded with the bottles, not as a method file |
| Modes | Single quad SCAN / SIM (and QQQ / MRM where the vendor reader exposes them) — see Compatibility |
Reader add-in: AgilentOpenLabDataProvider. Reads OpenLab CDS acquisition data for chromatogram extraction and sample discovery. Support DLLs live under:
C:\Program Files\Quanto\AddIns\VendorSupportFiles\Agilent\
Do not mix these DLLs with another Quanto build.
Method import
| Source | Add-in (class) | What you point at | What comes in |
|---|---|---|---|
| OpenLab CDS processing method | AgilentOpenLabMethod |
.pmx processing method (folder, .sirslt / .rslt, or the file itself) |
Expected compounds, ISTD role/link, signal / EIC m/z, RT windows, curve hints |
Import: Method → Load / Import — Replace or Append (Method design).
Acquisition method .amx is not a quant method — do not import it as the Quanto method.
Vendor methods do not set Quanto’s Calibration mode; new work defaults to Initial calibration unless you change it.
OpenLab coverage (short)
| Piece | Supported? |
|---|---|
| Data | Yes — AgilentOpenLabDataProvider for .dx / AcqData |
| Method import | Yes — AgilentOpenLabMethod for processing methods (.pmx) |
Acquisition method .amx |
Not a quant method — do not import as the Quanto method |
Contrast with MassHunter and ChemStation
| Vendor | Data you point at | Method import | Index / conversion |
|---|---|---|---|
| OpenLab CDS | .dx / AcqData via AgilentOpenLabDataProvider |
.pmx via AgilentOpenLabMethod |
OpenLab path — not MassHunter MSTree2.bin |
| MassHunter | .D + AcqData\ via AgilentMassHunterDataProvider |
.m / .quantmethod.xml or method-from-.D |
May write MSTree2.bin if missing |
| ChemStation / MSD | .D with data.ms / dataSim.ms |
.M + qdb.mth |
Native MSDChem — no index conversion |
Wrong expectations (treating OpenLab .dx as MassHunter .D, or importing .amx as a quant method) cause empty extracts or empty compound lists. Confirm which vendor created the file.
Related
- Compatibility — full OpenLab checklist
- Installation and folders —
AgilentOpenLabMethod.dllunder MethodImporter - Reports, import, and export —
.pmxvs data bottles - Set up an analysis
- Agilent MassHunter
- Agilent ChemStation / MSD
- Troubleshooting