User guides
IT install and sizing, OpenLab CDS, analysis setup, CalGroup, Method Validation, calibration, reports, and grids.
Flat color, Segoe UI, bottle and curve diagrams. Download A4 PDFs for the site, or read the HTML in a browser.
IT / administrators
Installation and folders
Program Files, add-ins, Local AppData, Public Documents, .qtb / .qtm / layouts, licenses.
Silent deploy
/VERYSILENT checklist, .NET 10 Desktop x64, no post-install launch, TDA optional.
Licensing
21-day grace, 30-day old data, instrument serial .lic, network LicenseFolder, prerelease expiry.
Validation notes
No Part 11 / audit / e-sign in codebase; controlled install, licenses, methods, exports.
Hardware and performance
CPU, RAM, SSD, network; measured Analyze times; PC and file-server sizing.
Headless / post-acquisition reporting
Quanto.Console CLI: import, Analyze, save method, report/export without the WPF UI.
Compatibility
Single/triple quad, SIM/MRM/SCAN; MassHunter / ChemStation / OpenLab CDS / SCIEX / Shimadzu / Waters MassLynx data and methods.
Agilent ChemStation / MSD
.D with data.ms / dataSim.ms, Scan/Sim/ScanAndSim, native MSDChem, .M + qdb.mth.
SCIEX WIFF
.wiff, multi-sample #n, MRM-centric extract, Clearcore2, method from WIFF.
Shimadzu LabSolutions LCD
.lcd, MRM/SRM-centric extract, LabSolutions IO, method from LCD.
Waters MassLynx
.raw folders, MRM + TIC, MassLynxRaw, method from data.
Analysts
Getting started
About 15 minutes: example IFRA batch, Analyze, calibration, export report.
Set up an analysis
Bottle types, OpenLab .pmx, CalGroup, doses/fortified, report workbooks, Analyze.
Method design
Keys, CalGroup, Origin/blank corr, Method Validation, RecPct and limits.
CalGroup & standard addition
Group bottles that share a curve; Calibration vs StdAdd mode; vs Initial/Bracket.
ESTD initial calibration
External standard, multi-level, one curve.
Blank offset
Put blank response on the curve as intercept; Blank use; what you see after Analyze.
Blank concentration
Subtract blank concentration toward NativeConc; Blank use; vs Blank offset; Solvent notes.
ISTD initial calibration
Internal standard, ratios, dose IS.
Bracket calibration
Cal sets around samples, per-bracket curves.
Key Review
Multi-instrument AcqKeys, QntKeys, SmpKey pick.
Method Validation
Method-wide curves, recoveries, and limit flags after Analyze.
Result limits & flags
RecPct / DevPct / RecFlag, MinCurveR2, response and qualifier limits.
Multi-batch dose responses
Partial update of stored calibration levels.
Manual integration
PeakValues boundaries, host metrics, 2% filter, area threshold, override/restore.
Reports, import, and export
Vendor / .qtm in, Q. reports, Excel / PDF / method out.
Report formulas
Full Q.* catalog, named refs, HideIf* / ShowIfTrue, V* plots.
Sample metadata extraction
Add Samples Extraction table - RegEx to AcqKey / Type / Dose.
Grids: interact and configure
Column fill, sort, freeze, navigator.
Workspace and layouts
Default.qtl, dockable panels, limited shortcuts, Shift splash.
Troubleshooting